Approximately calculated absorption coefficients for the surface of the Richfon partition

Calculated on basis of the area of absorption measured per partition for a surface of 3,60 m2

Absorption coefficients per Richfon partition 1310 x 1610 mm.

Absorption coefficients per Richfon partition 1310 x 1610 mm:

 100 Hz=0,60 A(m2)    800 Hz=2,86 A(m2)
 125 Hz=0,71 A(m2)  1000 Hz=3,12 A(m2)
 160 Hz=1,09 A(m2)  1250 Hz=3,09 A(m2)
 200 Hz=1,24 A(m2)  1600 Hz=3,01 A(m2)
 250 Hz=1,35 A(m2)  2000 Hz=3,02 A(m2)
 315 Hz=1,70 A(m2)  2500 Hz=3,00 A(m2)
 400 Hz=1,92 A(m2)  3150 Hz=2,83 A(m2)
 500 Hz=2,35 A(m2)  4000 Hz=2,74 A(m2)
 630 Hz=2,63 A(m2)   5000 Hz=2,54 A(m2)


Sound absorption data are measured in accodance with ISO 354 by Delta Acoustics & Vibration.